?url_ver=Z39.88-2004&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Adc&rft.relation=http%3A%2F%2Fwww.eledia.org%2Fstudents-reports%2F795%2F&rft.title=Robust+Diagnosis+of+Microstrip+Planar+Phased+Arrays+Through+a+Compressive+Sensing+Approach&rft.creator=SALUCCI%2C+Marco&rft.creator=GELMINI%2C+Angelo&rft.creator=OLIVERI%2C+Giacomo&rft.creator=MASSA%2C+Andrea&rft.subject=A+WC+Next+Generation+Wireless+Communications&rft.subject=M+CS+Compressive+Sensing&rft.description=This+work+deals+with+the+detection+of+faulty+radiators+in+real+microstrip+patches+planar+phased+arrays.+Towards+this+goal%2C+the+diagnosis+problem+at+hand+is+formulated+within+a+probabilistic+compressive+sensing+(CS)+framework+in+order+to+avoid+the+fulfillment+of+the+restricted+isometry+property+(RIP)+by+the+involved+measurement+operator.+A+customized+Bayesian+CS+solution+approach+is+then+developed+to+yield+robust+and+reliable+guesses+of+the+antenna+under+test+(AUT)+status+by+also+taking+into+account+all+mutual+coupling+effects+arising+in+realistic+operative+conditions.+Some+numerical+benchmarks+are+shown+to+assess+the+effectiveness+of+the+proposed+diagnosis+tool+when+considering+a+variation+of+the+antenna+size+and+failure+rate%2C+as+well+as+a+change+of+the+amount+of+noise+on+processed+far-field+data.&rft.publisher=ELEDIA+Research+Center+-+University+of+Trento&rft.date=2019&rft.type=Monograph&rft.type=NonPeerReviewed&rft.format=text&rft.language=en&rft.identifier=http%3A%2F%2Fwww.eledia.org%2Fstudents-reports%2F795%2F1%2FRobust_Diagnosis_of_Microstrip_Planar_Phased_Arrays_Through_a_Compressive_Sensing_Approach.v2.pdf&rft.identifier=++SALUCCI%2C+Marco+and+GELMINI%2C+Angelo+and+OLIVERI%2C+Giacomo+and+MASSA%2C+Andrea++(2019)+Robust+Diagnosis+of+Microstrip+Planar+Phased+Arrays+Through+a+Compressive+Sensing+Approach.++Technical+Report.+ELEDIA+Research+Center+-+University+of+Trento.+++++